  1 g5v-2 pcb relay miniature relay for signal circuits  wide switching power of 10 a to 2 a.  high dielectric strength coil-contacts:1,000 vac; open contacts: 750 vac.  conforms to fcc part 68 requirements.  ag + au clad bifurcated crossbar contacts and fully sealed for high contact reliability.  new 150-mw relays with high-sensitivity. ordering information model number legend specifications  coil ratings standard models r c fcc classification contact form contact type contact material enclosure ratings model standard dpdt bifurcated crossbar ag + au-clad fully sealed g5v-2 high-sensitivity g5v-2-h1 rated coil voltage note: when ordering, add the rated coil voltage to the model number. example: g5v-2 12 vdc 1. contact form 2: dpdt 2. classification h1: high-sensitivity 3. rated coil voltage 3, 5, 6, 9, 12, 24, 48 vdc g5v - - vdc 13 2 rated voltage 3 vdc 5 vdc 6 vdc 9 vdc 12 vdc 24 vdc 48 vdc rated current 166.7 ma 100 ma 83.3 ma 55.6 ma 41.7 ma 20.8 ma 12 ma coil resistance 18 w 50 w 72 w 162 w 288 w 1,152 w 4,000 w coil inductance (h) (ref. value) armature off 0.04 0.09 0.16 0.31 0.47 1.98 7.23 armature on 0.05 0.11 0.19 0.49 0.74 2.63 10.00 must operate voltage 75% max. of rated voltage must release voltage 5% min. of rated voltage max. voltage 120% of rated voltage at 23 c power consumption approx. 500 mw approx. 580 mw
2 g5v-2 g5v-2 high sensitivity models note: 1. the rated current and coil resistance are measured at a coil temperature of 23 c with a tolerance of 10%. 2. operating characteristics are measured at a coil temperature of 23 c.  contact ratings note note: p level:  60 = 0.1 x 10 ? 6 /operation  characteristics rated voltage 3 vdc 5 vdc 6 vdc 9 vdc 12 vdc 24 vdc 48 vdc rated current 50 ma 30 ma 25 ma 16.7 ma 12.5 ma 8.33 ma 6.25 ma coil resistance 60 w 166.7 w 240 w 540 w 960 w 2,880 w 7,680 w coil inductance (h) (ref. value) armature on 0.18 0.46 0.70 1.67 2.90 6.72 20.1 armature off 0.57 0.71 0.97 2.33 3.99 9.27 26.7 must operate voltage 75% max. of rated voltage must release voltage 5% min. of rated voltage max. voltage 180% of rated voltage at 23 c 150% of rated voltage at 23 c power consumption approx. 150 mw approx. 200 mw approx. 300 mw item standard models high sensitivity models load resistive load (cos f = 1) rated load 0.5 a at 125 vac; 2 a at 30 vdc 0.5 a at 125 vac; 1 a at 24 vdc contact material ag + au-clad rated carry current 2 a max. switching voltage 125 vac, 125 vdc max. switching current 2 a 1 a max. switching power 62.5 va, 60 w 62.5 va, 24 w failure rate (reference value) 0.01 ma at 10 mvdc item standard models high sensitivity models contact resistance 50 m w max. 100 m w max. operate time 7 ms max. release time 3 ms max. bounce time operate: approx. 0.3 ms release: approx. 1.5 ms max. operating frequency mechanical: 36,000 operations/hr electrical: 1,800 operations/hr (under rated load) insulation resistance 1,000 m w min. (at 500 vdc) dielectric strength 1,000 vac, 50/60 hz for 1 min between coil and contacts 1,000 vac, 50/60 hz for 1 min between con- tacts of different polarity 750 vac, 50/60 hz for 1 min between contacts of same polarity 1,000 vac, 50/60 hz for 1 min between coil and contacts 1,000 vac, 50/60 hz for 1 min between con- tacts of different polarity 500 vac, 50/60 hz for 1 min between contacts of same polarity impulse withstand voltage 1,500 v (10 x 160 s) between coil and contacts (conforms to fcc part 68) vibration resistance destruction: 10 to 55 to 10 hz, 0.75-mm single amplitude (1.5-mm double amplitude) malfunction: 10 to 55 to 10 hz, 0.75-mm single amplitude (1.5-mm double amplitude) shock resistance destruction: 1,000 m/s 2 (approx. 100g) malfunction: 200 m/s 2 (approx. 20g) destruction: 1,000 m/s 2 (approx. 100g) malfunction: 100 m/s 2 (approx. 10g) endurance mechanical: 15,000,000 operations min. (at 36,000 operations/hr) electrical: 100,000 operations min. (at 1,800 operations/hr) ambient temperature operating: - 25 c to 65 c (with no icing) operating: - 25 c to 70 c (with no icing) ambient humidity operating: 5% to 85% weight approx. 5 g
3 g5v-2 g5v-2  approved standards ul478, ul1950, ul508 (file no. e41515)/csa c22.2 no.0, no.14 (file no. lr24825) engineering data contact form coil ratings contact ratings g5v-2 g5v-2-h1 dpdt 3 to 48 vdc 0.6 a, 125 vac (general use) 0.6 a, 110 vdc (resistive load) 2 a, 30 vdc (resistive load) 0.5 a, 125 vac (general use) 0.2 a, 110 vdc (resistive load) 1 a, 24 vdc (resistive load) maximum switching power g5v-2 ambient temperature vs. maximum coil voltage g5v-2 endurance g5v-2 switching current (a) switching voltage (v) switching current (a) endurance (x10 operations) 3 ambient temperature (
4 g5v-2 g5v-2 dimensions note: 1. all units are in millimeters unless otherwise indicated. 2. orientation marks are indicated as follows:  terminal arrangement/ internal connections (bottom view) mounting holes (bottom view) tolerance:


▲Up To Search▲   

 
Price & Availability of G5V-2-H1-6VDC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X