1 g5v-2 pcb relay miniature relay for signal circuits wide switching power of 10 a to 2 a. high dielectric strength coil-contacts:1,000 vac; open contacts: 750 vac. conforms to fcc part 68 requirements. ag + au clad bifurcated crossbar contacts and fully sealed for high contact reliability. new 150-mw relays with high-sensitivity. ordering information model number legend specifications coil ratings standard models r c fcc classification contact form contact type contact material enclosure ratings model standard dpdt bifurcated crossbar ag + au-clad fully sealed g5v-2 high-sensitivity g5v-2-h1 rated coil voltage note: when ordering, add the rated coil voltage to the model number. example: g5v-2 12 vdc 1. contact form 2: dpdt 2. classification h1: high-sensitivity 3. rated coil voltage 3, 5, 6, 9, 12, 24, 48 vdc g5v - - vdc 13 2 rated voltage 3 vdc 5 vdc 6 vdc 9 vdc 12 vdc 24 vdc 48 vdc rated current 166.7 ma 100 ma 83.3 ma 55.6 ma 41.7 ma 20.8 ma 12 ma coil resistance 18 w 50 w 72 w 162 w 288 w 1,152 w 4,000 w coil inductance (h) (ref. value) armature off 0.04 0.09 0.16 0.31 0.47 1.98 7.23 armature on 0.05 0.11 0.19 0.49 0.74 2.63 10.00 must operate voltage 75% max. of rated voltage must release voltage 5% min. of rated voltage max. voltage 120% of rated voltage at 23 c power consumption approx. 500 mw approx. 580 mw
2 g5v-2 g5v-2 high sensitivity models note: 1. the rated current and coil resistance are measured at a coil temperature of 23 c with a tolerance of 10%. 2. operating characteristics are measured at a coil temperature of 23 c. contact ratings note note: p level: 60 = 0.1 x 10 ? 6 /operation characteristics rated voltage 3 vdc 5 vdc 6 vdc 9 vdc 12 vdc 24 vdc 48 vdc rated current 50 ma 30 ma 25 ma 16.7 ma 12.5 ma 8.33 ma 6.25 ma coil resistance 60 w 166.7 w 240 w 540 w 960 w 2,880 w 7,680 w coil inductance (h) (ref. value) armature on 0.18 0.46 0.70 1.67 2.90 6.72 20.1 armature off 0.57 0.71 0.97 2.33 3.99 9.27 26.7 must operate voltage 75% max. of rated voltage must release voltage 5% min. of rated voltage max. voltage 180% of rated voltage at 23 c 150% of rated voltage at 23 c power consumption approx. 150 mw approx. 200 mw approx. 300 mw item standard models high sensitivity models load resistive load (cos f = 1) rated load 0.5 a at 125 vac; 2 a at 30 vdc 0.5 a at 125 vac; 1 a at 24 vdc contact material ag + au-clad rated carry current 2 a max. switching voltage 125 vac, 125 vdc max. switching current 2 a 1 a max. switching power 62.5 va, 60 w 62.5 va, 24 w failure rate (reference value) 0.01 ma at 10 mvdc item standard models high sensitivity models contact resistance 50 m w max. 100 m w max. operate time 7 ms max. release time 3 ms max. bounce time operate: approx. 0.3 ms release: approx. 1.5 ms max. operating frequency mechanical: 36,000 operations/hr electrical: 1,800 operations/hr (under rated load) insulation resistance 1,000 m w min. (at 500 vdc) dielectric strength 1,000 vac, 50/60 hz for 1 min between coil and contacts 1,000 vac, 50/60 hz for 1 min between con- tacts of different polarity 750 vac, 50/60 hz for 1 min between contacts of same polarity 1,000 vac, 50/60 hz for 1 min between coil and contacts 1,000 vac, 50/60 hz for 1 min between con- tacts of different polarity 500 vac, 50/60 hz for 1 min between contacts of same polarity impulse withstand voltage 1,500 v (10 x 160 s) between coil and contacts (conforms to fcc part 68) vibration resistance destruction: 10 to 55 to 10 hz, 0.75-mm single amplitude (1.5-mm double amplitude) malfunction: 10 to 55 to 10 hz, 0.75-mm single amplitude (1.5-mm double amplitude) shock resistance destruction: 1,000 m/s 2 (approx. 100g) malfunction: 200 m/s 2 (approx. 20g) destruction: 1,000 m/s 2 (approx. 100g) malfunction: 100 m/s 2 (approx. 10g) endurance mechanical: 15,000,000 operations min. (at 36,000 operations/hr) electrical: 100,000 operations min. (at 1,800 operations/hr) ambient temperature operating: - 25 c to 65 c (with no icing) operating: - 25 c to 70 c (with no icing) ambient humidity operating: 5% to 85% weight approx. 5 g
3 g5v-2 g5v-2 approved standards ul478, ul1950, ul508 (file no. e41515)/csa c22.2 no.0, no.14 (file no. lr24825) engineering data contact form coil ratings contact ratings g5v-2 g5v-2-h1 dpdt 3 to 48 vdc 0.6 a, 125 vac (general use) 0.6 a, 110 vdc (resistive load) 2 a, 30 vdc (resistive load) 0.5 a, 125 vac (general use) 0.2 a, 110 vdc (resistive load) 1 a, 24 vdc (resistive load) maximum switching power g5v-2 ambient temperature vs. maximum coil voltage g5v-2 endurance g5v-2 switching current (a) switching voltage (v) switching current (a) endurance (x10 operations) 3 ambient temperature (
4 g5v-2 g5v-2 dimensions note: 1. all units are in millimeters unless otherwise indicated. 2. orientation marks are indicated as follows: terminal arrangement/ internal connections (bottom view) mounting holes (bottom view) tolerance:
|